Jim,
Thanks mucho! I will proceed with your suggestions.
73 Hardy N7RT


At 01:00 PM 7/17/2007 -0700, Jim Brown wrote:
>On Tue, 17 Jul 2007 12:33:51, Hardy Landskov wrote:
>
>>Any thoughts/experiences on which is better
>
>No question -- use a dedicated twisted pair for every circuit that 
>you want to control. Shielding is FAR less important than twisting. 
>Bond one of the conductors to ground at the sending end. This 
>provides the best noise immunity by far (and probably the least 
>problem with lightning) because it minimizes the loop area.
>
>73,
>
>Jim Brown K9YC
>
>
>