To: | "towertalk@contesting.com" <towertalk@contesting.com> |
---|---|
Subject: | Re: [TowerTalk] Control Lines and Grounding |
From: | "Jim Brown" <jim@audiosystemsgroup.com> |
Date: | Tue, 17 Jul 2007 13:00:25 -0700 |
List-post: | <mailto:towertalk@contesting.com> |
On Tue, 17 Jul 2007 12:33:51, Hardy Landskov wrote: >Any thoughts/experiences on which is better No question -- use a dedicated twisted pair for every circuit that you want to control. Shielding is FAR less important than twisting. Bond one of the conductors to ground at the sending end. This provides the best noise immunity by far (and probably the least problem with lightning) because it minimizes the loop area. 73, Jim Brown K9YC _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | [TowerTalk] Control Lines and Grounding, Hardy Landskov |
---|---|
Next by Date: | Re: [TowerTalk] Control Lines and Grounding, jeremy-ca |
Previous by Thread: | [TowerTalk] Control Lines and Grounding, Hardy Landskov |
Next by Thread: | Re: [TowerTalk] Control Lines and Grounding, jeremy-ca |