Towertalk
[Top] [All Lists]

Re: [TowerTalk] Questions about Irrigation Pipe for Verticals

To: "Red" <RedHaines@centurytel.net>
Subject: Re: [TowerTalk] Questions about Irrigation Pipe for Verticals
From: "Rick Karlquist" <richard@karlquist.com>
Reply-to: richard@karlquist.com
Date: Fri, 3 Nov 2006 23:18:34 -0800 (PST)
List-post: <mailto:towertalk@contesting.com>
You can use aluminum stovepipe tape to bridge the gap.

Rick N6RK



Red wrote:
> Hi, Gary;
>
> The coupling between a 2" OD and a 2.9" ID (the two pipes) is 46
> picoFarads per foot.  Guess we better put in the aluminum connections.
> The reactance of 46 pF is 124 Ohms at 28 MHz and 870 Ohms at 4 MHz, at
> one foot of overlap.  Hope I didn't lose a decimal place.  It's
> bedtime!  Better double check my calculations.
>
> 73 de Red