Towertalk
[Top] [All Lists]

Re: [TowerTalk] Ground wire impedance

To: "'Red'" <RedHaines@centurytel.net>,"'BenT'" <bthorson@4smps.com>,"'TowerTalk'" <towertalk@contesting.com>
Subject: Re: [TowerTalk] Ground wire impedance
From: "N2TK, Tony" <tony.kaz@verizon.net>
Date: Tue, 18 Jul 2006 09:41:30 -0400
List-post: <mailto:towertalk@contesting.com>
Took 5 years here in up state NY for the aluminum shield on the buried
hardline to become goo. It totally dissolved and left 2-3' open spaces with
no shield.

N2TK, Tony

-----Original Message-----
From: towertalk-bounces@contesting.com
[mailto:towertalk-bounces@contesting.com]On Behalf Of Red
Sent: Thursday, July 13, 2006 5:44 PM
To: BenT; TowerTalk
Subject: Re: [TowerTalk] Ground wire impedance

Hi, Ben and TTs;

Aluminum may fare better than copper in acidic ground but alkaline
ground will corrode aluminum.  Jim Lux raises an interesting suggestion
regarding sacrificial electrodes that might be generally useful where
the ground is strongly acidic or alkaline.  I hope to hear more about
that, and may turn to the books for some factual information.  Regarding
connections, one must use appropriate connectors and conductive
anti-corrosion compound, just as when making any clamped connection, be
it for copper, aluminum, iron, or any other metal exposed to the outdoor
environment or weld or braze the connections.

73 de WOØW

BenT wrote:

>Has anyone mentioned Aluminum wire? How does aluminum fare buried? Does
>it get corroded more quickly in the ground than copper?
>
>
>
_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>