To: | Red <RedHaines@centurytel.net>, g3rzp@g3rzp.wanadoo.co.uk,TowerTalk <towertalk@contesting.com> |
---|---|
Subject: | Re: [TowerTalk] RF on stainless steel |
From: | Peter Chadwick <g3rzp@g3rzp.wanadoo.co.uk> |
Reply-to: | g3rzp@g3rzp.wanadoo.co.uk |
Date: | Tue, 13 Jun 2006 17:01:27 +0200 (CEST) |
List-post: | <mailto:towertalk@contesting.com> |
Red, So in an Austenitic stainless steel, the only factor (other than frequency) affecting skin depth is the resistivity, and in that respect, stainless steel will be no different to any other non-magnetic material. Provided it's an Austenitic stainless, as opposed to one of the other varieties of stainless, such as the magnetic ones (some of which actually rust!). 73 Peter G3RZP _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [TowerTalk] RF on stainless steel, Red |
---|---|
Next by Date: | [TowerTalk] PL259 F-F, Mike Harris |
Previous by Thread: | Re: [TowerTalk] RF on stainless steel, Red |
Next by Thread: | [TowerTalk] 2006 Dayton Antenna Forum PowerPoint files now 100%available, Tim Duffy K3LR |
Indexes: | [Date] [Thread] [Top] [All Lists] |