Towertalk
[Top] [All Lists]

Re: [TowerTalk] Guying free-standing towers

To: towertalk@contesting.com
Subject: Re: [TowerTalk] Guying free-standing towers
From: Chris Pedder <chris@g3vbl.co.uk>
Date: Mon, 11 Apr 2005 13:37:14 +0100
List-post: <mailto:towertalk@contesting.com>
At 13:54 11/04/2005, n2ea wrote:

>Let's be clear, however:  Tensioned guys add load to a tower.
>Therefore, the tower will reach its material failure point
>sooner.

I beg to differ. The function of sensible guying is to prevent the tower 
from reaching its material failure point, or at least delay it.


>The function of the guys, is NOT to add strength to the
>system.  The function is to force a different failure mode,
>and the price of doing that will be reduced load rating, or
>earlier failure,

on the contrary, the function of guys IS to make the system stronger. After 
all, you do guy Rohn 25/45/55 don't you? Sensible guying here, and 
elsewhere, will increase the load rating and produce later failure.


Chris




_______________________________________________

See: http://www.mscomputer.com  for "Self Supporting Towers", "Wireless Weather 
Stations", and lot's more.  Call Toll Free, 1-800-333-9041 with any questions 
and ask for Sherman, W2FLA.

_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk