I did that ("wet set") for my tower with no problems. Just make certain
the conduit is large enough. Don't even *think* about anything less than
3" I.D., assuming few bends. 4" for the part in concrete might be better.
Also make certain the conduit run to the tower has a way to drain itself.
(I did a bad job on this. If I pull a rag through, it usually comes out
damp or wet. I sometimes use a shop vac to blow air through it for an
hour.)
Bill
W2WO
_______________________________________________
See: http://www.mscomputer.com for "Self Supporting Towers", "Wireless Weather
Stations", and lot's more. Call Toll Free, 1-800-333-9041 with any questions
and ask for Sherman, W2FLA.