Towertalk
[Top] [All Lists]

Re: [TowerTalk] (no subject)

To: <jimjarvis@ieee.org>, <towertalk@contesting.com>
Subject: Re: [TowerTalk] (no subject)
From: "W1GOR" <W1GOR@Maine.RR.Com>
Date: Sat, 19 Mar 2005 08:59:08 -0500
List-post: <mailto:towertalk@contesting.com>
Jim,

Two common sparkplugs, spaced about the same distance as the OWL, and 
threaded into a grounded block, will provide adjustable spark gaps that can 
be set to the desired breakdown needed to protect the OWL and still not arc 
when transmitting.

73, Larry - W1GOR


----- Original Message ----- 
From: "Jim Jarvis" <jimjarvis@comcast.net>
To: <towertalk@contesting.com>; <chchandler@adelphia.net>
Sent: Friday, March 18, 2005 11:19 PM
Subject: [TowerTalk] (no subject)
> The older arrl handbooks showed lightning gaps for open wire line.
> They had opposing sets of points, wide enough apart not to arc
> under normal power...but close enough that ESD or lightning would
> arc to ground.
> You could run copper ground strap up the exterior of the house,
> and implement this at the point where the OWL goes to the balun.
> n2ea
> jimjarvis@ieee.org

_______________________________________________

See: http://www.mscomputer.com  for "Self Supporting Towers", "Wireless Weather 
Stations", and lot's more.  Call Toll Free, 1-800-333-9041 with any questions 
and ask for Sherman, W2FLA.

_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk