Neil, when i first put it up i had a similar problem... hell no it
was identical !!!! I put a scope on the pulses back into the controller, and could see the pulse motor signals clearly messing up the "return" pulses... oisture got into the 8 conductor plug/jack assembly they provided. I chopped it off and used a 4 conductor euro electrical connector assembly. I see they are now using that exact junction connection...it was that moisture... it had me baffled and very pissed/// it has worked fine for several years ,once I got it cleared up.... it's on a us tower hdx572... bill At 12:25 PM 9/10/2004, Natan Huffman wrote: Friends, _______________________________________________ See: http://www.mscomputer.com for "Self Supporting Towers", "Wireless Weather Stations", and lot's more. Call Toll Free, 1-800-333-9041 with any questions and ask for Sherman, W2FLA. _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |