Subject: | [Towertalk] Ground rods for Polyphaser clamps |
From: | na4m@arrl.net (Phil Duff) |
Date: | Sat, 20 Apr 2002 16:50:39 +0000 |
At 11:07 4/20/2002 -0400, Wes Cosand wrote: >I have bought rods labeled 5/8" from both a consumer source and a >commercial distributor and they are actually 9/16". The Polyphaser clamps >for copper strips won't tighten up on the small rod. Anyone have a suggestion? > >Wes WZ7I I ran into the same problem. I made shims out of the copper strips to build up the rod diameter to fit the clamps. 73 Phil NA4M -. .- ....- -- -. .- ....- -- -. .- ....- -- -. .- ....- -- -. .- ....- -- Phil Duff NA4M na4m@arrl.net Georgetown, Texas |