"Wait a minute. When are you 'moving the temps up'? The sequence for Rohn
guyed tower of any caliber is to put up 4 sections, attach the permanent 
guys,
put up 4 more sections, attach guys, repeat as necessary. This means that 
you
can safely climb up to 4 sections of exposed tower. People do it every 
day."

>>>>>>>>>But not the first 4 sections of pier pin or rotating tower.

"Going down, level checking is by eye but guy tension bears checking with 
the
gauge.  When this is not done (at least in my admittedly limited
experience), a lot of time is spent diagnosing how things got out of kilter
and what major fix to apply, and this process takes longer and is
considerably riskier than lots of little checks and little fixes.

       "You check a tower for plumb and tension from the bottom up - not 
the
top down."

>>>>>>>>> By going down, I meant when you are taking a tower down. With 
regards to putting a tower up, you just said clearly n a few words what it 
took me many to say, and apparently not clearly.