In a message dated 99-02-04 11:55:51 EST, n4zr@contesting.com writes:
> I dunno, but on my Rohn 25, I wished I had the temps, particularly when I
> was working on attaching the 60-70 feet section with the only set of guys
> down at 31 feet. The long-period sway from just three unguyed sections was
> scarey, whether or not it was structurally risky.
>
Scary? Certainly can be. Structurally risky? Not really. That's why
professionals get paid for doing stuff like that.
Cheers, Steve K7LXC
--