Tom,

Please don't try to do that as you have described it.  The tower,
if it doesn't bend in the middle, will have stresses placed on it 
well over its design ratings.

I put up the first 80' of my Rohn 55 by lifting it from flat on the 
ground to its prepared base by lifting it with a helicopter.  Before 
doing so, I calculated the stresses involved and concluded that even
Rohn 55 would be overstressed if picked up 80' from the end.  As I 
recall,  I put the lift sling at about 50' from the ground end, so 
that there would not be more than 50' of unsupported tower.  That was 
well within the design criteria and it went up without a hitch (the 
NCDXF has a video tape of the full tower installation you can borrow
if it interests you).

My suggestion would be to have the crane pick the tower just above
the mid point, lift it up slightly, then set it down gently, letting
it lay over while the ground end is loosely secured.  Please control
the ground end of the tower at a safe distance with several people 
and long ropes.  I hate to think what a 100' tower could do to 
someone trying to control it by hanging on to it.

73, Jay O'Brien
    w6go@quiknet.com

--
FAQ on WWW:               http://www.contesting.com/towertalkfaq.html
Submissions:              towertalk@contesting.com
Administrative requests:  towertalk-REQUEST@contesting.com
Problems:                 owner-towertalk@contesting.com
Search:                   http://www.contesting.com/km9p/search.htm


<Prev in Thread] Current Thread [Next in Thread>