At 02:13 PM 8/12/97 +1000, you wrote:
>Gi'day from 'down under',
>
>I have been reading postings from this group with much interest for the
>last 2 months. This is my first post. I bought a few weeks ago a Hy-Gain
>TH6 DXX Thunderbird Yagi. I have disassembled it, cleaned all overlapping
>sections of tubing, coated them with Aluminox conductive paste and
>reassembled it. Prior to raising it on the tower, I would like to check
>that all traps are OK.
>
>I intend to look for 0.0 DC resistance over all trap connections. My
>question is:
>
>"what resonant frequencies should I look for using a GDO hooked onto the
>hot end of the traps and should I disconnect the traps fromn the elements
>when measuring the freguencies of resonance"?
>
>Also, is this the best way of ensuring the traps are OK? Should I be doing
>any other tests on the traps on the ground - e.g. using a noise bridge?
Hi Peter
I'm just going through the same thing.
10M traps 27.6Mhz
15M traps 20.6Mhz
(the above information is from Hygains web page)
You should use a grid dip meter to do the testing, but I could use some
direction here as well on how to do this. I have a meter, but I need some
advise on the coupling.
Regards...Mike VA3MW
--
FAQ on WWW: http://www.contesting.com/towertalkfaq.html
Submissions: towertalk@contesting.com
Administrative requests: towertalk-REQUEST@contesting.com
Problems: owner-towertalk@contesting.com
Search: http://www.contesting.com/km9p/search
|