Galvanized can be a problem in some soils. This is the reason that galvanized
ground rods are no longer recommended in most applications (I think ON4UN even
has a pictured of a rotted galvanized ground rod in his book).
Copper-clad steel ground rods are more common and will generally hold up much
better in typical soil conditions. I would assume the same would apply to
galvanized steel and copper radial wires. I'd be careful using galvanized wire
for radials without at first testing it to make sure it would last. It would be
a shame to invest time and effort in a radial system just to see it rot away in
a few years!
-Bill KB8WYP
> Note: The backstay we found of the old 1920's Belfast radio station was
> galvanized iron. The galvanized surface was in good condition after so many
> years in the ground) In the aging process have wondered how Zinc oxide
> compared with copper oxide. (Copper-weld vs zinc coated electric fence
> wire) Zinc is not nearly as good to start with.
>
> 73
> Bruce-k1fz
>