Topband
[Top] [All Lists]

Topband: Need help feeding tower on 160 AND 80

To: topband@contesting.com
Subject: Topband: Need help feeding tower on 160 AND 80
From: Brian Machesney <nekvtster@gmail.com>
Date: Tue, 25 Oct 2011 10:07:12 -0400
List-post: <topband@contesting.com">mailto:topband@contesting.com>
Gang,

I have an 80-ft tower topped by an KT34XA (elements insulated from 32-ft
boom) and 40-2CD (only reflector electrically connected to 22-ft boom). I
have 8 x 50-ft lengths of 4-ft wide welded, galvanized steel fence for a
ground screen. No other radials.

I have successfully matched this on 160 with about 350-pF series capacitor
to a 45-ft #12 gamma wire spaced about 3-ft from the tower.

I also want to feed the tower on 80. I have been hoping that the 160 gamma
wire would "disappear" electrically when it is open-circuited. Given the
complex configuratino of the GAP vertical antennas, this may be but a faint
hope. I'm having trouble creating a good match on 80 with a simple gamma
feed scheme.

Has anyone on the reflector tried to feed the same tower on two bands?

Please reply off-reflector.

Thanks and 73,

Brian K1LI
_______________________________________________
UR RST IS ... ... ..9 QSB QSB - hw? BK

<Prev in Thread] Current Thread [Next in Thread>