If the bridge is still in the circuit, that .2 ohm reading is the secondary
winding of the transformer.
If it does end up being the bridge, I recommend you remotely mount the new one
somewhere. I put mine on the back side of the front panel. Use BIG wire. (At
least 12 gauge)
And use heat sink grease.
Sent from AOL Mobile Mail
-----Original Message-----
From: Robert S Jenkins <qrp@kg4kgl.net>
To: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Sent: Tue, Jun 27, 2017 12:59 PM
Subject: Re: [TenTec] 962 power supply {was 961 PWR Supply}
I just finished checking the bridge and I am getting0.2 ohms between the AC
terminals and AC to +. It looks shorted to me.
Robert
KG4KGL
> On Jun 27, 2017, at 11:42, Joe Papworth via TenTec <<a
> href="mailto:tentec@contesting.com">tentec@contesting.com</a>> wrote:
>
> I've had that bridge fail 2 or 3 times in 19 years. There's a 40 amp version
> that is physically identical to the 25 amp one.
> (NTE5342. ECG5342, etc)
> Since I went to that one some years ago, it has never failed again.
>
> Sent from AOL Mobile Mail
>
>