Do you still have the Paragon's S meter ?
On Thursday, October 29, 2015 1:08 PM, Rodney <w3krq@dejazzd.com> wrote:
I still have this complete with 14 relays for sale these relays are surface
mount. This would be good insurance at 110.00 when it cost 110.00 labor at
TenTec.
-----Original Message-----
From: Rodney
Sent: Saturday, October 24, 2015 5:32 PM
To: Discussion of Ten-Tec Equipment
Subject: Re: [TenTec] Relays for a Paragon. Hopefully......
I have a low pass board for a Ten Tec Eagle . I though I needed a relay
found out the trouble was on the tuner board. I now have a complete board
for the Eagle if I had sent the Eagle down for repairs it would have cost me
shipping and 110.00 for labor plus parts, It cost me 190.00 for the board, I
no longer have the Eagle so I am selling the low pass board for 140.00
shipped.
-----Original Message-----
From: Wade Staggs
Sent: Saturday, October 24, 2015 5:17 PM
To: Discussion of Ten-Tec Equipment
Subject: Re: [TenTec] Relays for a Paragon. Hopefully......
*Thanks Peter,*
* If we can't get OEM? My plan will now be to
replace them all. And thanks again for the advise.*
* 73 from Wade/KJ4WS*
On Sat, Oct 24, 2015 at 3:56 PM, Peter Frenning [OZ1PIF] <peter@frenning.dk>
wrote:
> Den 24-10-2015 kl. 21:57 skrev Wade Staggs:
>
>> *Paul, at Ten Tec says that the Relays for the Low Pass Filter Board for
>> the Paragon, are no longer available. Written on the white body of the
>> relay is Wabash and the part # on the relay is 1925-3-2 ...... I am
>> finding
>> them pretty Unobtainium from all of my usual sources also. Does anyone
>> have
>> a decommissioned Paragon with a good Low Pass Filter Board? Or any spares
>> of this relay? We have found some Wabash Reed Relays that are a perfect
>> Sub. Exact Pin Out and Dimensions. The relays we found do the exact same
>> job in a Collins KWM-380. I just hate to use Non OEM Parts, no matter how
>> close the match is.*
>> * 73 to All from
>> Wade/KJ4WS*
>>
>> Please note, if you have to go the second source route, that you have to
> pair the relays so that a given band will be using to identical relays,
> (same close/open characteristics and current consumption).
>
> Several years ago, while I still owner my Paragon, I had to go that route,
> and Paul at TT stressed the point to me (was also very helpful with
> obtaining alternative relays)
>
> --
> Vy 73 de OZ1PIF/5Q2M, Peter
>
> ******************************************
> ** If it sounds too good to be true -- **
> ** it is! **
> ** If it sounds about right -- make **
> ** sure you can afford to be wrong! **
> ** **
> ** -- Robert Heinlein: **
> ** "Time enough for love" **
> ******************************************
> email: peter(no-spam filler)@frenning.dk
> http://www.frenning.dk/oz1pif.htm
> Ph. +45 4619 3239/ +45 2332 9464
> Snailmail:
> Peter Frenning
> Ternevej 23
> DK-4130 Viby Sj.
> Denmark
> ******************************************
>
> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> http://lists.contesting.com/mailman/listinfo/tentec
>
--
*Living one day at a time with Jesus as my Savior. But, still having Fun.*
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
|