Why is braid to be eschewed especially inside the shack?

On May 15, 2014, at 10:56 PM, Jim Brown wrote:

> On 5/15/2014 7:45 PM, Carter wrote:
>>> Again, bond all equipment together at the power supply and forget abt a 
>>> dedicated external ground.
>> I can try removing the external ground. I currently have 3/4" wide single 
>> piece of braid going from the radio to the PS to the amp to an outside 
>> ground (total length from last unit in line to the hole in the basement wall 
>> is less than 5 feet). 
> 
> The proper bonding is CHASSIS-TO-CHASSIS of interconnected equipment. One of 
> those chassis MUST be bonded to the power system green wire, to the antenna 
> system entry panel, to the power system ground, and to all other grounds in 
> the building.
> 
> 73, Jim K9YC