Likely a defective relay on the Low Pass filter board for that band. 
Check the diodes on the board.  Schematics are available for download
from the Tentec website.

73
Bob, K4TAX


Disclosure:

I am a Tentec Ambassador and receive compensation per the Ambassador
program.  Otherwise, I have no affiliation with Tentec.



> My Omni VI Plus will not put out any power on 20 Meters. It works fine on
> all
> other bands. When I try to transmit on 20 Meters I get no output power
> but the
> collector current goes to about twice the normal for same output on other
> bands.
> I have all of the correct voltages for the the relays on the BPF board
> and the
> LPF. Board I can hear the relays or possibly relay clicking on the LPF.
> Recieve
> on 20 is fine. Anyone experience this problem? if so what did you find
> was the
> cause. I suspect one of the  20 m LPF components or one of the 20 m
> relays. Any
> help or guidance would be appreciated.
> Thank
> Jack WN5A
> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> http://lists.contesting.com/mailman/listinfo/tentec
>


_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec

<Prev in Thread] Current Thread [Next in Thread>