To: | Discussion of Ten-Tec Equipment <tentec@contesting.com> |
---|---|
Subject: | Re: [TenTec] TT 509 Argonaut Sticking Relay |
From: | Stuart Rohre <rohre@arlut.utexas.edu> |
Reply-to: | Discussion of Ten-Tec Equipment <tentec@contesting.com> |
Date: | Tue, 19 May 2009 16:23:34 -0500 |
List-post: | <tentec@contesting.com">mailto:tentec@contesting.com> |
If the measurement of reed relay coil voltage shows a drop immediately on unkeying the PTT, and if degaussing the relay does not fix that, you may have pitted contacts that are arcing and welding with transmit currents.. If that turns out to be likely, replacement is the only solution. This reed relay is used for changeover from transmit to receive. Stuart Rohre K5KVH _______________________________________________ TenTec mailing list TenTec@contesting.com http://lists.contesting.com/mailman/listinfo/tentec |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [TenTec] Orion 2.063Xg, John T. Fleming |
---|---|
Next by Date: | Re: [TenTec] TT 509 Argonaut Sticking Relay, Jim Younce |
Previous by Thread: | Re: [TenTec] TT 509 Argonaut Sticking Relay, geoffrey mendelson |
Next by Thread: | Re: [TenTec] TT 509 Argonaut Sticking Relay, Jim Younce |
Indexes: | [Date] [Thread] [Top] [All Lists] |