will 20 amp breakers be enuff, or should I go for 22 amps..thanks.
----- Original Message -----
From: "Carl Moreschi" <n4py@earthlink.net>
To: "tentec" <tentec@contesting.com>
Sent: Saturday, April 30, 2005 12:05 PM
Subject: [TenTec] Omni VI power supply
>
> Just add one of the AIRPAX magnetic circuit breakers in line with your
> supply voltage. These breakers trip in a few milliseconds and are what
> TenTec used to recommend for this problem. There was quite a discussion
> of
> these on this reflector a year or two ago. The part number to get is
> T11-1-20.0A-01-11C-V. I seem to remember there was a place in Florida
> where these could be ordered.
>
> Carl Moreschi N4PY
> Franklinton, NC
>> ----- Original Message -----
>> From: "denton" <denton@oregontrail.net>
>> To: "Discussion of Ten-Tec Equipment" <tentec@contesting.com>
>> Sent: Saturday, April 30, 2005 2:57 PM
>> Subject: [TenTec] Omni VI power supply
>>
>>
>> > I have sent my Omni VI back to TT (again) to have the finals replaced.
>> > According to Scott I need something that will shut down when the Omni
> goes
>> > into ocillation.
>> > Thus I am asking what power supplies the TT herd is using for Omni
>> > VI's.
>> > I can put out a want for the Omni's matching supply, but would also
>> > like
>> to
>> > take a look at other things...thanks.
>> >
>> >
>> > _______________________________________________
>> > TenTec mailing list
>> > TenTec@contesting.com
>> > http://lists.contesting.com/mailman/listinfo/tentec
>>
>
> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> http://lists.contesting.com/mailman/listinfo/tentec
>
>