There are two issues, and I don't see either addressed completely in the
FLEX documentation, but I didn't see any warnings either. They are:
1. Can the transmitter run at 100% power for extended periods of time? RTTY
is a 100% duty cycle mode. When transmitting, you are transmitting at full
power.
2. Can the transmitter be run at 100% power and still produce a clean
signal? Most 12 volt PAs do not do 100 watt RTTY as clean as they do 50-75
watts. --73, Mike, WV2ZOW
On Thu, Jun 2, 2016 at 5:08 PM, Jeff Stai <wk6i.jeff@gmail.com> wrote:
> On Thu, Jun 2, 2016 at 12:46 PM, Stanley Zawrotny <k4sbz.stan@gmail.com>
> wrote:
>
> > No xcvr should be run at more than 50% power for RTTY.
> >
>
> RTTY contesting is effectively 50% duty cycle, at least until you need to
> respond to someone who wants a ragchew. I have run RTTY contests on a K3,
> and all kinds of FT1000 at full power. I have also run a K2 with a fan on
> the heat sink at full power. ;) They all handle it without stress.
>
> 73 jeff wk6i
>
>
>
>
> --
> Jeff Stai ~ wk6i.jeff@gmail.com
> Twisted Oak Winery ~ http://www.twistedoak.com/
> Facebook ~ http://www.facebook.com/twistedoak
> _______________________________________________
> RTTY mailing list
> RTTY@contesting.com
> http://lists.contesting.com/mailman/listinfo/rtty
>
_______________________________________________
RTTY mailing list
RTTY@contesting.com