You could always listen to it.

73, Pete N4ZR
Check out the new Reverse Beacon Network
web server at<http://beta.reversebeacon.net>.
For spots, please use your favorite
"retail" DX cluster.

On 6/6/2022 4:24 PM, Hare, Ed, W1RFI wrote:
Actually, much powerline noise is rather steady, so it will show up as a solid 
block on a waterfall.  That is diagnostic that the noise is not coming from a 
switcher, but will not differentiate conclusively between electrical noise and 
perhaps noise caused by something not powerline-related at all.  The waterfall 
will not really identify 60- or 120-Hz modulation, so demodulating in AM and 
looking at the resultant audio is an important step.

Ed


________________________________
From: RFI<rfi-bounces+w1rfi=arrl.org@contesting.com>  on behalf of Jim 
Brown<jim@audiosystemsgroup.com>
Sent: Monday, June 6, 2022 1:45 PM
To:rfi@contesting.com  <rfi@contesting.com>
Subject: Re: [RFI] Power Line Radiated Interference Limits

On 6/6/2022 4:28 AM, Hare, Ed, W1RFI wrote:
You can also make a .wav or .mp3 file and run it through a free program called 
'Audacity" and analyze that spectrum, with the understanding that your receiver 
bandwidth is usually limited below 200 Hz or so, so that 120-Hz component may be 
reduced in amplitude.
The best diagnostic tool, by far, to identify power line noise, as
opposed to electronic noise, is a broadband WATERFALL of either a
receiver's IF or RF. Powerline noise and lightning static is arcing, and
will show up as horizontal lines on a slow waterfall.

Electronic noise is the harmonics of square waves used in switch-mode
power supplies and other power control electronics like variable-speed
motor controllers, which show up as vertical humps of noise spaced at
10-50kHz, and microprocessor clocks, which sound like carriers and show
up as narrow vertical lines.

Power line and other impulse noise is present at all frequencies, but is
best chased at the highest frequencies where it can be heard.
Traditional techniques apply. Electronic noise must be chased on the
frequencies where it is heard.

More on this in this here.
http://k9yc.com/KillingReceiveNoise.pdf  and
http://k9yc.com/KillingRXNoiseVisalia.pdf

73, Jim K9YC
_______________________________________________
RFI mailing list
RFI@contesting.com
http://lists.contesting.com/mailman/listinfo/rfi
_______________________________________________
RFI mailing list
RFI@contesting.com
http://lists.contesting.com/mailman/listinfo/rfi
_______________________________________________
RFI mailing list
RFI@contesting.com
http://lists.contesting.com/mailman/listinfo/rfi

<Prev in Thread] Current Thread [Next in Thread>