Pete et al--

In my 51 years of experience in ham radio including 24 years in the Army Signal 
Corps, I have long learned that lightning is like the 800-lb gorilla: it goes 
where it wants to go despite all the preventative measures one takes. I come 
from upstate NY where lightning storms are quite common and I know hams who 
have had their rigs, antennas, and homes or shacks destroyed even though they 
had lightning protection devices, e.g., surge and lightning protectors. 
Lightning doesn't need a direct hit to affect anything electronically attached 
to the point of contact. In one instance, Tony WB2DTW (now an SK) had a 
lightning strike on his beam some 40 ft from his home. The strike hit the 
antenna, traveled down the coax to his rigs in the garage, then proceeded along 
the power line into his home and eventually found a suitable ground. Everything 
in between was destroyed from his rigs to the kitchen blender including a major 
section of his garage. He forgot one thing (see below).

That said, at least some measures might be taken. Better something than nothing 
if for no other reason than a little peace of mind. There is no such thing as a 
lightning-proof system. But best protection I've seen are old-fashioned 
lightning rods such as are commonly found on top of barns but mounted on top of 
a mast, mounted on top of a second parallel mast, and/or on top of a house... 
anything to divert the lightning strike away from rigs and other (expensive) 
things. Main thing is to have the lightning rods ABOVE the antennas and any 
nearby structures.

Grounding is important but no matter how sophisticated a ground system might 
be, there's other precautions one might take, e.g., if a lightning/electrical 
storm appears imminent, disconnect the coax going into your rig(s) and get it 
as far away from everything as possible (Tony had done this yet his rigs were 
still destroyed.), and UNPLUG the rigs and the other expensive items such as 
refrig, freezer, TV, computers and peripherals. If there's a nearby (say 20+ 
miles) lightning storm, you'll hear the crashes on whatever band if you're on 
the air. Same/same landline telephone via which lightning will travel (I know 
of people killed while on the phone.).

Some details: http://www.iceradioproducts.com/10.html (see Paragraph 3). The 
League also provides a wealth of information on the subject 
http://www.arrl.org/lightning-protection .

But again, lightning goes wherever it wants.

73 de Fred Stevens K2FRD
Prescott, AZ

 

At 12:00 PM -0700 1/7/12, rfi-request@contesting.com wrote:
>
>
>Message: 1
>Date: Sun, 01 Jul 2012 10:28:56 -0400
>From: Pete Smith N4ZR <n4zr@contesting.com>
>Subject: [RFI] Single-point grounding
>To: RFI List <rfi@contesting.com>
>Message-ID: <4FF05EA8.6040707@contesting.com>
>Content-Type: text/plain; charset=ISO-8859-1; format=flowed
>
>I'm not sure exactly where I should post this, but suspect that this
>group probably has more relevant expertise than most, so please bear
>with me.
>
>In the last year, I have had two expensive episodes.  In both cases, my
>transceiver's RS-232 transceiver was fried during a lightning storm, and
>several knowledgeable people suggested a difference in chassis potential
>between computer and transceiver as the reason.  Their prescription for
>avoiding a repetition was simple - connect the chassis of all of the
>units to a single-point ground.
>
>My solution - which I'm asking people to critique - was to fabricate an
>L-shaped, roughly 3x5 foot ground bus made from 3/4" copper tubing,
>which I mounted on the back of my L-shaped operating desk. All joints
>are silver-soldered. I then connected each of the affected units to the
>bus with very short and heavy stranded wire, and connected the end of
>the bus to my grounded shack entry panel (in a double-hung window).
>
>The DC resistance of the ground bus is very low, but the length
>approximates a quarter wave on 10 meters, and with the units connected
>near the ends of the bus, I wonder if I'm feeling a false sense of
>security about the likely behavior of the bus during a nearby lightning
>event.  Would I be better off (or no better) running heavy conductors
>from each unit to the entry panel, even if they would have to be
>similarly long? Or should I just give up and plan on disconnecting the
>RS-232 connection whenever weather approaches?
>