Hi Dan,
yes I can do link test from client side to base station and vice versa,
but client won't register on base station.
Ivan
Dan Metcalf wrote:
I Have a similar issue on an ap-1000, can you do a wireless link test to
your clients?
-----Original Message-----
From: karlnet-bounces@WISPNotes.com
[mailto:karlnet-bounces@WISPNotes.com] On Behalf Of Ivan Romanic
Sent: Friday, March 12, 2004 3:28 PM
To: Karlnet Mailing List
Subject: [Karlnet] Strange station lockups (SG-4250)
Hi everyone,
we have very strange issue with one of our base stations (SG-4250, 8
user v4.44-02). From time to time it locks up without any obvious
reason. We can ping the station and it is responding to commands via
ethernet port but wireless seems to be inactiove (reboot etc.). It is
KN-200 board in metal enclosure wiht 12VDC PoE.
Even better, we had same issues with SR-4250 licence on
RG-1100 unit and
then we thought it is hardware issue so we replaced it with above
mentioned KN-205 board.
Both stations had same clinents - 5 of them, 2 KN-100, 2
RG-1100 and one
Ubicom device.
We have activated TurboCell Access List which have helped a bit.
Anyone knows what is going on ?
Thanx,
Ivan Romanic
technical coordinator
MadNet doo
Jadranska 17
26000 Pancevo
Serbia&Montenegro
www.madnet.co.yu _______________________________________________
Karlnet mailing list
Karlnet@WISPNotes.com
http://lists.wispnotes.com/mailman/listinfo/ka> rlnet
--
[This
E-mail scanned for viruses by Declude Virus]
_______________________________________________
Karlnet mailing list
Karlnet@WISPNotes.com
http://lists.wispnotes.com/mailman/listinfo/karlnet
|