I Have a similar issue on an ap-1000, can you do a wireless link test to
your clients?
> -----Original Message-----
> From: karlnet-bounces@WISPNotes.com
> [mailto:karlnet-bounces@WISPNotes.com] On Behalf Of Ivan Romanic
> Sent: Friday, March 12, 2004 3:28 PM
> To: Karlnet Mailing List
> Subject: [Karlnet] Strange station lockups (SG-4250)
>
>
> Hi everyone,
>
> we have very strange issue with one of our base stations (SG-4250, 8
> user v4.44-02). From time to time it locks up without any obvious
> reason. We can ping the station and it is responding to commands via
> ethernet port but wireless seems to be inactiove (reboot etc.). It is
> KN-200 board in metal enclosure wiht 12VDC PoE.
>
> Even better, we had same issues with SR-4250 licence on
> RG-1100 unit and
> then we thought it is hardware issue so we replaced it with above
> mentioned KN-205 board.
>
> Both stations had same clinents - 5 of them, 2 KN-100, 2
> RG-1100 and one
> Ubicom device.
>
> We have activated TurboCell Access List which have helped a bit.
>
> Anyone knows what is going on ?
>
> Thanx,
> Ivan Romanic
> technical coordinator
>
> MadNet doo
> Jadranska 17
> 26000 Pancevo
> Serbia&Montenegro
> www.madnet.co.yu _______________________________________________
> Karlnet mailing list
> Karlnet@WISPNotes.com
> http://lists.wispnotes.com/mailman/listinfo/ka> rlnet
> --