To: | <amps@contesting.com> |
---|---|
Subject: | Re: [Amps] 10 KW CCS ON 6M...USING THE 3CX-6000A7... PART 12 |
From: | "Peter Voelpel" <dj7ww@t-online.de> |
Date: | Thu, 1 Dec 2022 20:31:06 +0100 |
List-post: | <mailto:amps@contesting.com> |
With smaller vacuum caps, closer to the grid and only 2" separation between them, Q could be much lower and more L for a proper coil might be used. 73 Peter -----Original Message----- From: Amps [mailto:amps-bounces@contesting.com] On Behalf Of jim.thom <I have a bigger coil in my 2m amp and my 6m amp has quite a few turns. <73 and thanks, Alek, VK6APK. ## The tube is run at 5.5 kv @ 3amps under load. Plate load Z = 1019 ohms. With a conventional PI network, the MINIMUM Q we can use is a whopping 24. That results in an insane 79 amps of RF flowing through the conventional _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [Amps] 10 KW CCS ON 6M...USING THE 3CX-6000A7... PART 12, jim.thom jim.thom@telus.net |
---|---|
Next by Date: | Re: [Amps] 10 KW CCS ON 6M...USING THE 3CX-6000A7... PART 12, Alek Petkovic |
Previous by Thread: | Re: [Amps] 10 KW CCS ON 6M...USING THE 3CX-6000A7... PART 12, jim.thom jim.thom@telus.net |
Next by Thread: | Re: [Amps] 10 KW CCS ON 6M...USING THE 3CX-6000A7... PART 12, Alek Petkovic |