Amps
[Top] [All Lists]

[Amps] 300Hz sidebands

To: "amps@contesting.com" <amps@contesting.com>
Subject: [Amps] 300Hz sidebands
From: Conrad PA5Y <g0ruz@g0ruz.com>
Date: Sun, 23 May 2021 16:35:57 +0000
List-post: <mailto:amps@contesting.com>
Hi all.

I have several tetrode amplifiers that run from a 3PH 50Hz supply. With the 
advent of the FT8 I have become aware that I have 300Hz sidebands at only 
-50dBc, this is obviously unacceptable. The supplies are from Rhode and 
Schwartz and are very well made and use an 8uF oil filled capacitor for 
smoothing. Some of the EU amateurs will know the supply, it is known as an IN 
026 A1.

I suspect that this problem has always been there.

What is interesting is that Class AB1 or Class C, 100W out or 1kW out from the 
PA the sidebands are -50dBc. I did consider the G1 and G2 supplies but 300Hz 
suggests the 3PH supply and this happens with 3 different amplifiers, the only 
common factor is the HT supply. If it was ripple, I would have expected this to 
change depending on Anode current, but it doesn't. Unless of course the 
capacitor is completely shot. I will check that next, it's a little difficult 
to get to.

The PSU details can be found here:
https://www.dropbox.com/s/l71qj1g3qv7zh73/Servive%20Doc%20UHN284.pdf?dl=0

Any ideas?

Regards

Conrad



_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>