Amps
[Top] [All Lists]

[Amps] SB-220 Problem has me stumped, looking for some guidance on what

To: amps@contesting.com
Subject: [Amps] SB-220 Problem has me stumped, looking for some guidance on what to look at next
From: Colin Cooper via Amps <amps@contesting.com>
Reply-to: Colin Cooper <evinruding@yahoo.com>
Date: Mon, 14 Jan 2019 15:21:50 -0500
List-post: <mailto:amps@contesting.com>
Hello everyone,
I bought a SB-220 as a project at Hamvention in Ohio, I think I paid about 400 
dollars for it, It was pretty dirty but complete. I wanted to restore one of 
these to compliment my SB200 that I have already restored.
The problem:
When the amp is plugged in and turned on resting at idle, it seems to be fine. 
However when you key the amplifier the Plate and the Grid meters  are both 
PEGGED. The meter lights also dim as to indicate that the amp is using quite a 
bit of current.

Things I have changed/updated:
I Installed the Harbaugh electronics boards, so it has a new cap string as well 
as a new HV and metering board.
I also installed a new TX/RX relay and the “Soft Key” so that my new radios 
could key the amp without damage.
I Directly grounded the grids on the tube sockets, removing the mica capacitors.

Things I have checked:
HV: HV is good, the cw/tune / ssb switch works I have 2400 volts in cw and 3000 
in ssb
Tubes: I also own two other tl-922 kenwood amps that use the same tubes, so I 
swapped a set of proven good eimac 3-500z’s from one of those amps into this 
one - no change
120-vs-220 voltage: it does this regardless of how the input power is configured
The Bias Diode circuit on the harbach board, I triple checked my 
assembly/installation and see no problems
The 120v Bias/relay Power supply is working.
The Bias relay: I initially thought this was a bias issue and so I triple 
checked the configuration of the bias circuit. I have also reconfigured the 
bias circuit to resistive bias and there was no change. The grid and plate 
meters still peg when keying the amp.
The center tap of the filament transformer: It does not appear to be shorted to 
ground.
The amp acts like something somewhere is shorting to ground but only when the 
amp is Keyed up.  


I would really really appreciate any help or guidance that the group could 
provide on what to look at next.

Thank you and 73
Colin Cooper
K8MDX, Grass lake Michigan

_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps