Oh… I mistyped them. It should be Crydom CSD2425P
Sent from Mail for Windows 10
From: David G4FTC
Sent: den 9 januari 2019 02:29
To: Amps reflector
Subject: Re: [Amps] SSR in amp PS not working as expected
I did a google search for the Crydom CSD2525P SSR but I can't find any
datasheet - could it be a "special" for some particular application and is
incompatible with what you are trying to do?
David G4FTC
________________________________
From: Amps <amps-bounces@contesting.com> on behalf of Ulf Tjerneld
<ulf@sm0nor.com>
Sent: 05 January 2019 10:59
To: Amps reflector
Subject: [Amps] SSR in amp PS not working as expected
Hi All,
I start with the question:
Is there anything around SSR:s in general or anything in particular around the
Crydom CSD2525P that I don’t’ understand when used as breakers and step -start
in a HV PS?
And the background:
After a few years off the reflector and amp building I recently dusted off my
big-ultimate-amp-project and took up the work again.
This winter’s focus is the PS. I thought it could be nice to use SSR:s in the
AC-circuit for breaking and step-start. I have never used SSR:s before, but I
expected it to work as planned as I perceive them as pretty simple devices.
Anyhow, I bought three surplus SSR:s off Ebay, Crydom CSD2525P rated at 25A,
and built a standard breaking and step-start circuit around them.
Everything was tested with a low voltage 230/12 Volt small transformer on the
bench. It works as expected; the two SSR:S in the 230V line switches on and the
third SSR shortens the inrush resistor after about a second of delay.
But, when testing with the HV-transformer, it doesn’t work.
The HV transformer is boxed in the chassis and disconnected from all secondary
loads. The HV-output is isolated and off from anything in the circuit. I
measure voltage on the 105 volt secondary winding. The only things outside of
the box is the multimeter and the 12Volt DC control voltage. After applying
control voltage the SSR:s in the AC line actuates and the transformer starts to
hum, which it shouldn’t, and after a second the step-start SSR actuates and the
transformer starts to hum loudly. The reading on the 105V secondary was close
to zero.
The transformer in itself is a custom made 2KVA toroid beast wound for me in
Germany in 2013. With the breaking circuit out of the loop, the transformer is
almost inaudible and delivers as expected in the 105V secondary,
So, the question is: is there anything around SSR:s in general or anything in
particular around the Crydom CSD2525P that I don’t’ understand? Please advise! 😊
/73’s SM0NOR - Ulf
Sent from Mail for Windows 10
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|