Amps
[Top] [All Lists]

Re: [Amps] Last question on Amp Supply LK-500 no tune

To: amps@contesting.com
Subject: Re: [Amps] Last question on Amp Supply LK-500 no tune
From: AJ <iamfromcanadaalso@gmail.com>
Date: Sun, 18 Feb 2018 19:52:27 -0500
List-post: <mailto:amps@contesting.com>
On Sun, 18 Feb 2018 09:19:58 -0500
Ham H <kghams@gmail.com> wrote:

> I now have the amp working perfectly with one exception. 160 meters
> has no output. When I looked at the schematic they had a fixed
> loading capacitor for 160 that says it was factory selected.
> 
> Well the pin on the bandswitch where that cap would go has no
> connection. All bandswitch wiring is origianal and still has green
> paint on all connections and the pin where this cap should go has
> never had solder. Looks like it was never installed in the factory.
> 
> Does anyone have any idea what ball park value that cap is?  I know
> other bands have air var caps that go to 500 pF .
> 
> Thanks
> 
> Gary K4MT
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps


Hi Gary

-If you are talking about section A there is no connection at the 160
-pin of the band-switch according to the schematic.

-If you are talking about the load side section C it is 0.0014 uf 5kv
-according to the schematic.


AJ___ VE3HJ
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>