To: | amps@contesting.com |
---|---|
Subject: | [Amps] Last question on Amp Supply LK-500 no tune |
From: | Ham H <kghams@gmail.com> |
Date: | Sun, 18 Feb 2018 19:02:14 -0500 |
List-post: | <mailto:amps@contesting.com> |
Thanks all for the answers. I found the problem. The plate tuning cap for 160 M has 5 100PF 5 KV caps padding it. One of them was shorted out and even had a piece blown out of it. Replaced them with new caps and now 160 is working. I see the missing cap may be 1400 PF but says selected in factory. Will have to find one as I dont have any in junk box. Thanks for the advice Gary K4MT _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | [Amps] Selector band antenna switch, Juan Pablo Ravinale |
---|---|
Next by Date: | Re: [Amps] Last question on Amp Supply LK-500 no tune, AJ |
Previous by Thread: | Re: [Amps] Last question on Amp Supply LK-500 no tune, AJ |
Next by Thread: | [Amps] Last question on Amp Supply LK-500 no tune, Jim Thomson |
Indexes: | [Date] [Thread] [Top] [All Lists] |