Thanks all for the answers. I found the problem. The plate tuning cap for 160 M has 5 100PF 5 KV caps padding it. One of them was shorted out and even had a piece blown out of it. Replaced them with new caps and now 160 is working. I see the missing cap may be 1400 PF but says selected in factory. Will have to find one as I dont have any in junk box. Thanks for the advice Gary K4MT _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |