Hi Jim,
Why not leave the grid grounded but, just measure the cathode and plate
currents then subtract to calculate the grid current?
73 & Good morning,
Marv WC6W
http://qsl.net/wc6w/
--------------------------------------------
On Mon, 11/28/16, Jim W7RY <jimw7ry@gmail.com> wrote:
Subject: [Amps] 8877 Grid Connection DC or Not
To: "AMPS" <amps@contesting.com>
Date: Monday, November 28, 2016, 7:00 PM
Has anyone run the grid of an 8877
not connected to ground as far as DC is concerned?
I really need to meter the grid current by bypassing the
grid to ground with capacitors and several 10 ohm resistors
in order to meter grid current. Metering grid current by the
CT of the filament transformer, and the – of the power
supply cant be done. Because the power supply – is
directly grounded.
Anyone had luck doing this?
Thanks 73
Jim W7RY
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps