There are charts that relate blower speed and impeller diameter to cfm.
Since the Eimac listing is for CCS commercial duty we hams get some slack at
least for SSB/CW.
EBM-Papst appears to have the tightest tolerances and lowest friction which
do cut down on the noise, especially when using a lower rpm motor.
Carl
KM1H
----- Original Message -----
From: "Charles Bibb" <zedkay@telepak.net>
To: <amps@contesting.com>
Sent: Tuesday, August 07, 2012 3:52 PM
Subject: [Amps] Blower recommendations 8877 amp.
>
> I'm looking for specific blower recommendations for a HB 8877 amp.
> (blower maker and model #).
>
> Everyone says use a Papst blower because they are quieter. I use a
> Papst fan in my HB 2x3-500 amp.
>
> I have several blowers here. The ones that obviously move enough air
> are WAY too loud! The quiet ones I'm not sure about. They seem to
> move plenty of air, but don't produce the amount of water level
> change recommended by Eimac.
>
> I built a liquid tube manometer gauge to measure the back
> pressure. Only the loudest can deliver the minimum 0.41 inch change
> in water level that Eimac recommends for the 8877. Surely, there are
> compromises that work just fine.
>
> What blower are you guys using in your single 8877
> amps? Recommendations, anyone?
>
> 73,
> Charles - K5ZK
>
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>
>
> -----
> No virus found in this message.
> Checked by AVG - www.avg.com
> Version: 10.0.1424 / Virus Database: 2437/5183 - Release Date: 08/07/12
>
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|