Does running the blower after shut down apply to a tube like the
4CX1500A [5V @ 42A]? I don't see any thing about that in the Eimac spec
sheet.
I've wondered about that for the amp I am building. I have a variac on
the filament transformer because I wanted to set the voltage and my
filament transformer is over-sized for the requirements of the tube.
Your design sounds good because I have wondered how to prevent
forgetting to reset the variac after shut down. I never thought of a
constant voltage transformer on the filament circuit. That's a good
idea too.
On the other hand, if I revise the filament circuit to 240 VAC I have a
properly sized filament transformer for the tube so I don't have to
worry about inrush current.
David
KW4DH
On 6/3/2011 6:44 AM, Jim Thomson wrote:
> Date: Thu, 2 Jun 2011 15:11:39 -0600
> From: "Jim Garland"<4cx250b@muohio.edu>
> Subject: [Amps] Should a blower run after amp shutdown?
> To:<amps@contesting.com>
> Message-ID:<AEA880D1565E4930BDDA3599FE9CA146@JimsOffice>
> Content-Type: text/plain; charset="us-ascii"
>
> Like many homebrewers, I've always built a timer into my amps that powers
> the blower for a couple of minutes after killing power to the amplifier.
> Today, however, in a conversation with another builder, I began to question
> whether this is actually a useful feature. (Obviously, exhausting hot air
> from the enclosure after powering off an amplifier does no harm, but the
> issue is whether any presumed benefit is worth the effort building in this
> feature.) Here's my reasoning.
>
> ### On big external anode tubes like the 3CX-3000A7 / 3CX-6000A7, 3x10 etc...
> all with thoriated tungsten fils, Eimac sez to run the blower for 15 mins
> after the
> amp is shut off...and that includes the fil being shut off as well.
>
> ## here's the procedure I use on both a 3CX-3000A7 [ 7.5v @ 50A]...
> and also a 3CX-6000A7 [7.0V @ 80A] . Separate 240 vac feed into the
> input of a 1kva Sola constant voltage xfmr. Output of Sola xfmr is fed into
> the
> input of a 0-240 vac @ 5A variac. Output of variac feeds the input of the
> dahl fil xfmr. Variac has a cam + microswitch on it's shaft. Microswitch
> contacts
> activate the coil of a dpdt relay.
>
> ## 1 x toggle switch for blower, and a 2nd toggle switch for the fil. Input
> of 2nd toggle gets it's power from the
> output of the 1st toggle. It's then a simple interlock. I can have the
> blower on and no fil, but not the other way around.
> The variac is used to slowly ramp up the fil V to desired level. When
> done for the night... the amp is placed into standby, B+
> is shut down, and then the fil is slowly ramped down to zero V. Blower is
> left on for 15 mins..then shut off.
>
> ## The 15 min blower over run is all automatic, done with an adjustable
> 'delay on' type timer. If I forget to ramp the variac down
> at 3 AM, I don't have to worry about fil inrush the next night. The cam +
> microswitch on the shaft of the variac takes care of that problem.
> The fil CAN'T come on until the variac shaft is rotated fully CCW,..and
> engages the cam / microswitch! Once the variac shaft is
> rotated fully CCW, the microswitch engages, and then feeds the juice to the
> coil of a dpdt relay.... whose contacts pass the regulated 240 vac
> into the input of the variac. It sounds more complicated than it actually
> is. It's all quite simple really.
>
> ## Cold resistance of a light bulb is only 1/10th it's hot resistance.
> Thoriated tungsten tubes are worse, only 1/12th.
>
> ## One day I had just the fil + blower only [ no B+] running on my
> 3CX-3000A7 amp. I shut off both the fil + blower
> at the same time..and removed the tube from socket 1 min later. I had the
> tube between my legs, while on a chair... adjusting
> a hose clamp around the top of the tube [ which held several layers of
> silicone rubber, used to shim the oversized chimney].
>
> ## The coaxial fil on the bottom of the 3x3 tube was warm... THEN started
> getting hotter and hotter and hotter. The fil
> was abt to burn my stomach ! My theory is/was... the heat inside the fil
> had migrated back out onto the coaxial fil.
>
> ## and the amp was in stand-by and NO B+ on at all...just fil + blower.
> From then on in...... blower over run was on for 15 mins
> as Eimac suggested..and with the fil OFF too. No point in having blower
> over run, with amp on standby..and fil still on.....not
> with 375/560 watt type fils.
>
> later.... Jim VE7RF
>
>
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>
--
"I predict future happiness for Americans if they can prevent the government
from wasting the labors of the people under the pretense of taking care of
them."
Thomas Jefferson
"We may consider each generation as a distinct nation, with a right, by the
will of its majority, to bind themselves, but none to bind the succeeding
generation, more than the inhabitants of another country."
Thomas Jefferson