I'd run the 572b's at about the same numbers as the 811's.
Benton wb5twc
On 1/21/2011 11:50 AM, Thomas F. Giella NZ4O wrote:
> I have an AL-811 running 572B's instead of 811's. The manual says for RTTY
> mode to use a maximum of 150 ma on the grid and 400 ma on the plate for the
> 811's.
>
> What would be the maximum grid and plate current that I could use on the
> 572B's on RTTY?
>
> 73& GUD DX,
> Thomas F. Giella, NZ4O
> Lakeland, FL, USA
> nz4o@tampabay.rr.com
>
> NZ4O Solar Space Weather And Geomagnetic Data Archive: http://www.nz4o.org
> NZ4O Daily LF/MF/HF/6M Radiowave Propagation Forecast:
> http://www.solarcycle24.org
>
>
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|