Amps
[Top] [All Lists]

Re: [Amps] AL-82 Blowing fuses on startup

To: w7ry@inbox.com, ww4cox@embarqmail.com, g.m.mcadams@comcast.net, amps@contesting.com
Subject: Re: [Amps] AL-82 Blowing fuses on startup
From: Gudguyham@aol.com
Date: Sun, 14 Nov 2010 17:39:45 -0500 (EST)
List-post: <amps@contesting.com">mailto:amps@contesting.com>
Not so Jim
 
 
In a message dated 11/14/2010 3:36:25 P.M. Eastern Standard Time,  
w7ry@inbox.com writes:

If the  step start relay were shorted, the fuse is by-passed.  In other  
words, the fuse is not in the circuit, it's shorted out by the relay  
contacts.

73
Jim  W7RY


--------------------------------------------------
From:  "Mitch Cox" <ww4cox@embarqmail.com>
Sent: Sunday, November 14, 2010  5:50 AM
To: "Gary McAdams" <g.m.mcadams@comcast.net>;  <amps@contesting.com>
Subject: Re: [Amps] AL-82 Blowing fuses on  startup

> Sounds like the step-start relay is welded. That's where I  would start.
>  ----- Original Message ----- 
>  From:  Gary McAdams
>  To: amps@contesting.com
>  Sent: Sunday,  November 14, 2010 8:47 AM
>  Subject: [Amps] AL-82 Blowing fuses on  startup
>
>
>  Hello Group.
>
>  Short  question: I have an AL-82 that has started to blow a fuse on 
>  start-up.
>
>  It doesn't do it every time, and when the fuse  is replaced the unit
>  starts OK and runs all day w/o problems.  This all started when I
>  re-arranged the shack. The unit is about  two years old.
>
>  The first time it happened, I checked the  AC input at ~248 volts. Is
>  this too high?
>
>   So, any ideas on what to look for or where to start? As I sit here  the
>  amp is on and running, but yesterday I had to replace a fuse  to get it
>  started. This is only twice that I've had to replace  the fuse, but
>  that's two times too many.
>
>   73 Gary WG7X
>   _______________________________________________
>  Amps mailing  list
>  Amps@contesting.com
>   http://lists.contesting.com/mailman/listinfo/amps
>
>
>   -----
>  No virus found in this message.
>  Checked by  AVG - www.avg.com
>  Version: 10.0.1153 / Virus Database: 424/3254  - Release Date: 11/13/10
>  _______________________________________________
> Amps mailing  list
> Amps@contesting.com
>  http://lists.contesting.com/mailman/listinfo/amps
>
>
>
>  -----
> No virus found in this message.
> Checked by AVG -  www.avg.com
> Version: 10.0.1153 / Virus Database: 424/3255 - Release  Date: 11/13/10
>  
_______________________________________________
Amps mailing  list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps