Hi Paul,
Acceptable on an indirectly heated tube.
This will cause trouble on a filamentary type as even though the filament is
structured to minimize the effect some modulation will occur. This is not
generally noticable with (50-)60Hz operation but, at 20-100Khz the sidebands
will be evident.
Also on a GG design, the filament choke will have substantial reactance at
the switcher frequency creating more problems...
73 & Good morning,
Marv WC6W
http://qsl.net/wc6w/
--- On Tue, 10/5/10, Paul Decker <kg7hf@comcast.net> wrote:
> From: Paul Decker <kg7hf@comcast.net>
>
> What if instead of DC, the square wave (triangle or
> whatever) from the switchers transformer were used?
>
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|