    C connector, HN, or even RG214 with connectors will work fine 
(commercial TX often use RG214 for 8kv in the States).  Otherwise buy a 
Millen connector & use HV cable- about $20-35 US on Ebay, but cheaper at 
hamfests.  If you use one of the RF coax connectors, just make damn sure you 
mark it as such in the event an unknowledgeable person decides it it an RF 
line...

    See you soon on 50 MHz TEP!

    73 Dave N3DB


----- Original Message ----- 
From: "Felipe Ceglia - PY1NB" <felipeceglia2@gmail.com>
To: <Amps@contesting.com>
Sent: Tuesday, January 12, 2010 3:17 PM
Subject: [Amps] which HV connector to use?


> Hi,
>
> I need to choose a connector for plug the HV power supply to RF deck.
> Which one to choose?
>
> Is the amphenol ms-3106a-2817s a good idea? This one has 15 pins, and is
> used on harris RF-110 to connect PS to RF deck, but RF110's PS is only
> 2200 volts.
> Do you have information if this will survive 3500vdc without arcing? I
> got a spec sheet for it, but that was not clearly stated.
>
> 73 TU,
>
> Felipe Ceglia - PY1NB
> -------------------------------------------------------------------------------------
> PR1T team member /// Rio DX Group member /// Araucaria DX Group member
> http://www.dxwatch.com /// http://reversebeacon.net /// 
> http://riodxgroup.dxwatch.com
>
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps 

_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>