Amps
[Top] [All Lists]

Re: [Amps] Henry 2KD-5

To: "Robert Perdue" <kc0hfl@cox.net>, <Amps@contesting.com>
Subject: Re: [Amps] Henry 2KD-5
From: "David J Windisch" <davidjw@cinci.rr.com>
Date: Fri, 7 Nov 2008 03:51:20 -0500
List-post: <amps@contesting.com">mailto:amps@contesting.com>
SWAG 1:

Trace the circuit out.  There probably is mis-wiring involving the (-) end 
of the HVPS and the Ig meter, eg, bleeder misconnected, or HVPS grounded 
directly to chassis, or . . . the meter switch?  Parts may have to be 
disconnected.

73 Dave W8FGX

----- Original Message ----- 
From: "Robert Perdue" <kc0hfl@cox.net>
To: <Amps@contesting.com>
Sent: Thursday, November 06, 2008 12:22 PM
Subject: [Amps] Henry 2KD-5


> Okay the Henry works 100% now here is the issue when the meter is in the 
> IG grid current position the meter pegs backwards I have checked the relay 
> all is fine there looked SNIP 

_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>