    Thanks for the great info Manfred.  I didn't get your email until after 
I sent my latest.  I agree 1000%, I can't use it as it is.  I think after a 
few hours running even at idle it would get hot enough to burn a winding, 
even with lots of air.
    Your paragraph on the air gap & eddy currents jolted my memory- when I 
unpacked this transformer the lower angle aluminum mounting stock was bent a 
bit on one corner, as if it had been dropped on that corner.  Everything 
else looked fine otherwise & I straightened the corner of the angle stock 
out easily with a large adjustable wrench.  However, the bolt right next to 
that corner is the one generating the 275 deg F heat, worse than the other 3 
by almost 100 deg.  Maybe when the bend occurred it dislocated the bolt, 
bringing it into contact with the core.
    I am going to pull the transformer out of the chassis & see what 
hardware I need to replace the bolts, as well as what size teflon tube will 
fit into the hole thru the core.  I hope there isn't too much varnish in 
there.  I'd consider formvar tape but I have not been able to locate 
anywhere to get it.  I suppose teflon will hold up better anyway.

    73 & thanks,
    Dave N3DB


----- Original Message ----- 
From: "Manfred Mornhinweg" <mmornhin@gmx.net>
To: <amps@contesting.com>
Sent: Saturday, May 03, 2008 10:09 PM
Subject: Re: [Amps] HV transformer issue


> Hi Dave,
>
> interesting problem, with those bolts!
>
> Firstly, I would not believe that they can get so hot from hysteresis
> losses. They are not really taking much magnetic flux at all, because
> they are separated from the laminations by the air gap made by the
> clearance between the bolts and the holes. As a consequence, replacing
> these bolts with nonmagnetic ones, such as stainless steel, will not
> help, or at least not because of any magnetic phenomena.
>
> The heat must be caused by an enormous current flowing through them, or
> more likely, a quite large current flowing through the poor connections
> made by the nuts on the surface they sit on. So, the obvious solution is
> to insulate them, at least one end. You say that the bolts are thinner
> than the holes' diameter. That's great, as it might allow you to use
> these insulating washers that also have a sort of little tube attached.
> Sorry for the poor description, but I mean insulating washers such as
> those used for mounting transistors on heat sinks, using metal bolts.
> Complementing the in-hole insulation with a tube made of paper is also a
> good idea.
>
> Regarding material of the bolts, what might help is using a material
> with poorer conductivity. After all, the best reason why transformer
> laminations are made of silicon steel is that this alloy has much higher
> resistance than carbon steel! That reduces eddy currents. It is possible
> that your problem comes mostly from eddy currents in the bolts, and in
> that case the only thing that would help is using a material with higher
> resistance. But I don't think this is the case, because of the air gap
> you have there, which should keep magnetic flux and thus eddy currents
> in the bolts rather low.
>
> If all else fails, use some longer pieces of angle stock so that you can
> install the clamping bolts outside the laminations, to keep them free of
> strong fields and make them easy to insulate.
>
> I would not use the transformer like it is, because such extreme heating
> of the bolts can cause more problems, in addition to being unnecessary
> power loss.
>
> Manfred, XQ6FOD.
>
> ========================
> Visit my hobby homepage!
> http://ludens.cl
> ========================
>
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>
> 


_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>