>Ive seen mention of that method Peter but how do you calculate the choke value?< I don't know, but I would work on the basis that the choke should offer 10 times the impedance of the PA at the lowest modulating frequency. So a 10Henry choke offering 18k ohms in the DC feed to the PA, and from the mod transformer via a capacitor witha reactance of about 1/10 of the PA load - say 4 mFd - should do the trick. It's a techniques some very QRO (100kW plus) broadcast tx's use. 73 Peter G3RZP _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |