Maybe Im a little dense but I have no idea what you are asking.
If the plate transformer runs on 240 and the rest on 120 you do not need a 
separate 120 line. Simply use one leg of the 240 line against the neutral. 
Real old 220 lines and EU stuff uses a 2 wire setup; its 3 wire in the USA.

Carl
KM1H


----- Original Message ----- 
From: "k7rdx" <k7rdx@charter.net>
To: "Amps Amps" <amps@contesting.com>
Sent: Saturday, July 07, 2007 11:09 PM
Subject: [Amps] Transformer question


>I have a 2kva isolation/240-120 step down transformer I want to use to 
>power
> a rf deck with 120v filament transformer&blower. Is it necessary to switch
> the 240 primary or can the primary be hooked directly to the ac mains thru
> fuses?Thanks in advance for your input..Jim K7RDX..