EP Swynar wrote:> > Now, on the MINUS side: > > -The FC-30 is specified for operation from 3.5-MHz to 30-MHz, inclusive: > because each FC-15 rod is only 3-1/2" long, it does not have enough > inductance for 160-meters; Assuming you're running connected as a grounded grid triode, the choke will appear as a shunt inductance to ground - can you simply choose the right capacitor to tune it to parallel resonance on 160m? Steve _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |