Amps
[Top] [All Lists]

Re: [Amps] 3CX800A7 Orientation

To: Larry <larry@w7iuv.com>
Subject: Re: [Amps] 3CX800A7 Orientation
From: R L Measures <r@somis.org>
Date: Wed, 16 Aug 2006 13:41:06 -0700
List-post: <mailto:amps@contesting.com>
On Aug 16, 2006, at 1:31 PM, Larry wrote:

> Bob,
>
> My Eimac data sheet for the 3CX800A7 (dated 1 Dec 83) on page 3,  
> mechanical:
>
> "The tube may be mounted in any position. If it is operated in an
> inverted (anode down) or horizontal position the SK-1916 chimney clamp
> assembly should be used for reliable retention."
>
> BTW the thing needs 33 CFM @ .88 inches water for cooling, assuming  
> 50°
> C and 5000 foot elevation. How you gonna get that in a MLA-2500?

A radial wheel centrifugal blower. Kooltronix makes them.
>
> 73, Larry
>
> Larry - W7IUV
> DN07dg
> http://w7iuv.com
>
>
>
> Bob Maser wrote:
>
>> Let me ask again since I only received one rather unsure response  
>> to my call
>> for help yesterday.
>>
>> Can the 3CX800A7( and the 3CPX800A7) be operated in the horizontal  
>> position?
>> Is it a definite no-no or just a bit risky?  I am considering  
>> putting the
>> tube into a MLA-2500 and cooling it would be lots simpler if I  
>> could mount
>> the tube horizontally.
>>
>> Thanks,
>> Bob  W6TR
>>
>> _______________________________________________
>> Amps mailing list
>> Amps@contesting.com
>> http://lists.contesting.com/mailman/listinfo/amps
>>
>>
>>
>>
>>
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>

R L MEASURES, AG6K. 805-386-3734
r@somis.org



_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps

<Prev in Thread] Current Thread [Next in Thread>