Bob,
My Eimac data sheet for the 3CX800A7 (dated 1 Dec 83) on page 3, mechanical:
"The tube may be mounted in any position. If it is operated in an
inverted (anode down) or horizontal position the SK-1916 chimney clamp
assembly should be used for reliable retention."
BTW the thing needs 33 CFM @ .88 inches water for cooling, assuming 50°
C and 5000 foot elevation. How you gonna get that in a MLA-2500?
73, Larry
Larry - W7IUV
DN07dg
http://w7iuv.com
Bob Maser wrote:
>Let me ask again since I only received one rather unsure response to my call
>for help yesterday.
>
>Can the 3CX800A7( and the 3CPX800A7) be operated in the horizontal position?
>Is it a definite no-no or just a bit risky? I am considering putting the
>tube into a MLA-2500 and cooling it would be lots simpler if I could mount
>the tube horizontally.
>
>Thanks,
>Bob W6TR
>