Subject: | Re: [Amps] grid resonance |
From: | "Tom W8JI" <w8ji@w8ji.com> |
Date: | Mon, 7 Aug 2006 16:42:49 -0400 |
List-post: | <mailto:amps@contesting.com> |
> Now here is the biggie that caused this thread....is the > grid on a 3-500Z > physically large enough to fall into "significant > electromagnetic > interaction" category, or is it in the "hard-wired" > category, or none of the > above? Of course it is large enough to have resonances at frequencies we might be interested in. We not only have to contend with lead lengths there is also considerable capacitance, both distributed and lumped at points (like that big grid support cone). Assuming the grid has some sort of problem based on a GDO meter dip is as bad as assuming a GDO can check a tank circuit or a tank component like an air variable for high impedances (parallel resonances). Anyway here's a sweep of 3-500Z's and 811A's. http://www.w8ji.com/grid_resonance.htm If you want to see tank voltage distribution in an SB220/221: http://www.w8ji.com/SB221/sb-221.htm 73 Tom _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [Amps] grid resonance, Jim Brown |
---|---|
Next by Date: | Re: [Amps] Estate sale - USed CB Gear for re-distribution, Dave, K2DP |
Previous by Thread: | Re: [Amps] grid resonance, Ian White GM3SEK |
Next by Thread: | Re: [Amps] grid resonance, R L Measures |