To: | r@somis.org |
---|---|
Subject: | Re: [Amps] Safety grounding - was Mains Isolation Transformer |
From: | Gudguyham@aol.com |
Date: | Wed, 5 Jul 2006 07:30:35 EDT |
List-post: | <mailto:amps@contesting.com> |
In a message dated 7/4/2006 4:01:14 P.M. Eastern Standard Time, r@somis.org writes: What guages for which wires would be required for a 4-conductor 50a outlet? assuming you bought a pre-fabed cable like Romex 6-3 w/ground the 3 insulated wires would be #6 and the bare bond wire would be #`10. In some instances you may reduce the size of the neutral based on the load. There are specific codes involved with the reduction of neutral size. Lou _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |
Previous by Date: | Re: [Amps] Safety grounding - was Mains Isolation Transformer, Gudguyham |
---|---|
Next by Date: | Re: [Amps] Safety grounding - was Mains Isolation Transformer, Peter Chadwick |
Previous by Thread: | Re: [Amps] Safety grounding - was Mains Isolation Transformer, Gudguyham |
Next by Thread: | Re: [Amps] Safety grounding - was Mains Isolation Transformer, Peter Chadwick |
Indexes: | [Date] [Thread] [Top] [All Lists] |