On Mar 8, 2006, at 6:40 AM, Partain, Chuck wrote:
> ok another easy question for you guru's
>
> what is an "acceptable" percentage for HVPS ripple?
>
> I see figures of up to 10%
A 4-1000A / 8166 with a 60 Hz, FWB, 7000v PS, using a 2uF filter C
produces no detectable ripple on a SSB signal.
>
> thought that was high, lets assume at operating current not
> into a R load but ready and hooked to the plate choke.
>
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>
>
Rich Measures, 805.386.3734, AG6K, www.somis.org
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|